Lamtec
Lamtec LT1 On Mounting Plate
Ask for Stock
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Preciseness:±0,2 Vol. % O2 after balancing on air value 21 % O2
(with Lambda-probe LS1)Setting time:<20 s on 90 % of final value (T90)
(with Lambda probe LS1 type 650 R 0001 and 450 mm MEV)Failure impact
Deviation by temperature
Deviation by pressure1,3 % of measurement value / 10 mbar pressure change / pressure compensation optionalAmbient temperature
- operation
- transport and storage
+10% / -15%, 48Hz...62Hz
To be used in grounded network lines only!Resolution0,01% over the whole rangeTime for being ready with LS11...2 hours after "POWER ON"
(with Lambda-probe LS1)Setting time:<20 s on 90 % of final value (T90)
(with Lambda probe LS1 type 650 R 0001 and 450 mm MEV)Failure impact
Deviation by temperature
1 % of measurement value / 10 K housing temperature Lambda probe LS1,
temperature compensation optional
Deviation by pressure1,3 % of measurement value / 10 mbar pressure change / pressure compensation optionalAmbient temperature
- operation
- transport and storage
0°C...+60°C
-40°C...+85°C
+10% / -15%, 48Hz...62Hz
To be used in grounded network lines only!Resolution0,01% over the whole rangeTime for being ready with LS11...2 hours after "POWER ON"
Approvals:
SIL 1 Confirmation:
DIN EN 61508:2011, part 1-7Suggested Products
10 products found