Measuring principle: | - Electromagnetic (flow)
- Thinfilm sensor (pressure)
- Thermistor (temperature)
|
Flow measuring ranges: | 0...10 l/min to 0...600 l/min |
Pressure measuring ranges: | 0...40 bar (0...4 MPa) bis 0...400 bar (0...40 MPa) |
Temperature measuring ranges: | Freely selectable between 0...99 °C |
Nominal widths: | - DN10, DN19 and DN25
- Optional with plug couplers DN10, DN12, DN19, DN25 or DN31
- Optional with socket nipples DN32 and DN50 (type SSKV heavy version)
|
Nominal pressure ranges: | 100 bar (10 MPa) to 500 bar (50 MPa) |
Electrical connection: | - Terminals and cable gland M25x1.5
- Machaczek connector type ME2A10
- Souriau connector series 845, size 1 or 2
- Hydrostar connector type SKK24
- Hydrostar connector type SKK45M
- Hirschmann connector type G4A5M
|
Output signal: | Current 4...20 mA two-wire interface |
Housing: | - Sensor: brass or bronze
- Electronic: bras
|
Electrode material: | 1.4571 (316Ti) |
Power supply: | 8.0...13.5 VDC |
Power consumption: | < 1 W |
Protection acc. to EN 60529: | IP 65 |
Vibration resistance - Endurance stress with sliding frequency acc. to EN 60068-2-6: | - Excitation mode: sine
- Frequency range: 5...500 Hz
- Amplitude: 5…15 Hz: 5.5 mm (peak), 15…500 Hz: 5 g
- df/dt: 1 oct / min
- Test directions: 3 directions (X, Y, Z)
- Test duration: approx. 70 min / direction
- Total test duration: approx. 3.5 h
- Test temperature: room temperature
|
Shock resistance - Acc. to EN 60068-2-27: | - Excitation mode: shock half – sine
- Shock duration: 18 ms
- Shock amplitude: 30 g
- No. of shocks: 3 per direction
- Test directions: 6 directions in space (± X, ± Y, ± Z)
- Total no. of shocks: 18
- Test temperature: room temperature
|
Marking acc. to 2014/34/EU (ATEX): | I M2 Ex ib I Mb (TEST 15 ATEX 0027) |
Ambient temperature: | -20...+80 °C |
Process temperature: | -20...+100 °C |
Measuring uncertainty: | Max. ± 2 % of end value, typ. ± 1 % |
Functional safety: | SIL 2 (acc. to EN 61508) |