- Products
- KSR Kuebler
- KSR Kuebler ELS Float Switch
KSR Kuebler
KSR Kuebler ELS Float Switch
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Mounting on engines, tanks, vessels or enclosures, where, due to a lack of space, installation within them is not possible Use for turbulent liquid levels such as in oil sumps in large engines, gearboxes etc. Pump and level control and monitoring of distinct filling levels Chemical, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power plants Process water and drinking water treatment
Special features of the level switch
Freely selectable switch position through fixing the float switch at the required level Large range of application due to the simple, proven functional principle For harsh operating conditions, long service life Operating limits:
- Operating temperature: T = -30 ... +150 °C
- Operating pressure: P = Vacuum up to 40 bar
- Limit density: ? ?600 kg/m3
Description of the level switch
In an external chamber (bypass chamber), a float with a permanent magnet moves on a guide tube in relation to the liquid level, following the principle of communicating vessels. Within the guide tube is fitted a reed contact (inert gas contact), which is energised, through the non-magnetic walls of the float and guide tube, by the approach of the float magnet. By using a magnet and reed contact the switching operation is non-contact, free from wear and needs no power supply. The contacts of the level switch are potential-free.
The switching functions always refer to a rising liquid level.
The level switch is simple to mount and maintenance-free, so the costs of mounting, commissioning and operation are low.