- Products
- HEIDENHAIN
- HEIDENHAIN LIDA 403 Exposed Linear Encoder
HEIDENHAIN
HEIDENHAIN LIDA 403 Exposed Linear Encoder
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Linear scale
LIDA 403
Measuring standard
Coefficient of linear expansion*
METALLUR scale grating on glass ceramic or glass; grating period 20 µm
?therm 8 · 10–6 K–1 (glass)
?therm = (0±0.5) · 10–6 K–1 (Robax glass ceramic)
Accuracy grade*
±1 µm (only for Robax glass ceramic), ±3 µm, ±5 µm
Baseline error
? ±0.275 µm/10 mm
Measuring length ML* in mm
240 340 440 640 840 1040 1240 1440 1640 1840 2040 2240 2440
2640, 2840, 3040 (ROBAX glass ceramic with up to ML 1640)
Reference marks*
LIDA 4x3: One at midpoint of measuring length; LIDA 4x3 C: Distance-coded
Mass
3 g + 0.1 g/mm measuring length
Scanning head
LIDA 48
LIDA 47
Interface
1 VPP
? TTL
Integrated interpolation*
Signal period
–
20 µm
5-fold
4 µm
10-fold
2 µm
50-fold
0.4 µm
100-fold
0.2 µm
Cutoff frequency –3 dB
? 400 kHz
–
Scanning frequency*
–
? 400 kHz
? 200 kHz
? 100 kHz
? 50 kHz
? 200 kHz
? 100 kHz
? 50 kHz
? 25 kHz
? 50 kHz
? 25 kHz
? 12.5 kHz
? 25 kHz
? 12.5 kHz
? 6.25 kHz
Edge separation a1)
–
? 0.100 µs
? 0.220 µs
? 0.465 µs
? 0.950 µs
? 0.100 µs
? 0.220 µs
? 0.465 µs
? 0.950 µs
? 0.080 µs
? 0.175 µs
? 0.370 µs
? 0.080 µs
? 0.175 µs
? 0.370 µs
Traversing speed1)
? 600 m/min
? 480 m/min
? 240 m/min
? 120 m/min
? 60 m/min
? 240 m/min
? 120 m/min
? 60 m/min
? 30 m/min
? 60 m/min
? 30 m/min
? 15 m/min
? 30 m/min
? 15 m/min
? 7.5 m/min
Interpolation error
±45 nm
–
Limit switches
L1/L2 with two different magnets; output signals: TTL (without line driver)
Electrical connection
Cable, 0.5 m, 1 m or 3 m, with 15-pin D-sub connector (male)
Cable length
See interface description, however limit: ? 20 m (with HEIDENHAIN cable)
Voltage supply
DC 5 V ±0.5 V
Current consumption
< 130 mA
< 150 mA (without load)
Vibration 55 Hz to 2000 Hz
Shock 6 ms
? 500 m/s2 (EN 60 068-2-6)
? 1000 m/s2 (EN 60 068-2-27)
Operating temperature
–10 °C to 70 °C
Mass Scanning head
Connecting cable
Connector
20 g (without cable)
22 g/m
32 g
* Please select when ordering
1) At a corresponding cutoff or scanning frequency