Scale
LIDA 207
Measuring standard
Coefficient of linear expansion
Steel scale tape; grating period 200 µm
?therm 10 x 10–6 K–1
Accuracy grade
±15 µm
Scale tape cut from roll*
3 m, 5 m, 10 m
Reference marks
Selectable every 100 mm
Mass Scale tape
Scale-tape carrier
20 g/m
70 g/m
Scanning head
LIDA 28
LIDA 27
Interface
1 VPP
TTL
Integrated interpolation*
Signal period
–
200 µm
10-fold
20 µm
50-fold
4 µm
100-fold
2 µm
Cut-off frequency
Scanning frequency
Edge separation a
? 50 kHz
–
–
–
? 50 kHz
? 0.465 µs
–
? 25 kHz
? 0.175 µs
–
? 12.5 kHz
? 0.175 µs
Traversing speed
? 600 m/min
? 300 m/min
? 150 m/min
Interpolation error
±2 µm
–
Electrical connection*
Cable, 1 m or 3 m, with 15-pin D-sub connector (male)
Cable length
See interface description, but ? 30 m (with HEIDENHAIN cable)
Power supply
DC 5 V ±0.25 V
Current consumption
< 155 mA
< 140 mA (without load)
Vibration 55 Hz to 2000 Hz
Shock 11 ms
? 200 m/s2 (EN 60068-2-6)
? 500 m/s2 (EN 60068-2-27)
Operating temperature
–10 °C to 70 °C
Mass Scanning head
Connecting cable
Connector
20 g (without cable)
30 g/m
32 g
* Please select when ordering