Specifications
LC 115
LC 115
LC 185
Measuring standard
Coefficient of linear expansion
DIADUR glass scale with absolute track and incremental track, grating period 20 µm
?therm 8 x 10–6 K–1
Accuracy grade*
±3 µm up to 3040 mm measuring length; ±5 µm
Measuring length ML* in mm
140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440
1540 1640 1740 1840 2040 2240 2440 2640 2840 3040 3240 3440 3640 3840
4040 4240
Functional safety
for applications up to
• SIL-2 according to EN 61 508• Category 3, PL 'd” according to EN ISO 13 849-1:2008–
PFH
15 x 10–9;
ML > 3040 mm: 25 x 10–9
(up to 6000 m above sea level)
–
Safe position1)
Encoder: ±550 ?m;
ML > 3040 mm: ±2050 µm
(safety-related meas. step SM = 220 ?m)
–
Mechanical connection: fault exclusions for loosening of the housing and scanning unit (page 21)
Interface
EnDat 2.2
Ordering designation
EnDat22
EnDat02
Measuring step At ±3 µm
At ±5 µm
0.001 µm
0.010 µm
0.005 µm
0.010 µm
Clock freq. (calc. time tcal)
? 16 MHz (? 5 µs)
? 2 MHz (? 5 µs)
Incremental signals
–
? 1 VPP (20 µm)
Cutoff frequency –3 dB
–
? 150 kHz
Electrical connection
Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block
Cable length
? 100 m2)
? 150 m2)
Voltage supply
DC 3.6 V to 14 V
Power consumption (max.)
3.6 V: ? 1.1 W; 14 V: ? 1.3 W
Traversing speed
? 180 m/min (max. acceleration in measuring direction ? 100 m/s2)
Required moving force
? 4 N
Vibration 55 Hz to 2000 Hz
effecting the
Shock 11 ms
Housing: ? 200 m/s2 (EN 60 068-2-6)
Scanning unit: ? 200 m/s2 (EN 60 068-2-6)
? 300 m/s2 (EN 60 068-2-27)
Operating temperature
0 °C to 50 °C
Protection EN 60 5293)
IP53 when installed according to instructions in the brochure, IP64 with sealing air from DA 400
Mass
0.55 kg + 2.9 kg/m measuring length
* Please select when ordering
1) Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics)
2) With HEIDENHAIN cable; clock frequency ? 8 MHz
3) In the application the LC must be protected from the intrusion of particles and liquids