ESN
ESN Type 8513 Control Unit
Contact with us! 24 business hours (excluding weekends and holidays) to confirm stock status and estimated delivery time.
Control Unit with/without pulse extension and running-time limitation
The Type 8513 control unit serves the purposes of power supply, remote control, function monitoring, and switch-position reporting on switch drive motors based on the 3-lead principle (inwards lead, outwards lead, and return lead).
Technical Data
Dimensions
W/H/D = 100/70/115 mm
Housing
ABS / polystyrol
Fastening
2 drilled holes as in drilling diagram
Safety category
Housing IP 40; Terminals IP 10
Ambient temperature
-20°C to +60°C
Fuse / breaker
as required (standard = 6.3A)
Command buttons
2 (for “On” and “O?”)
Contact connection
max. AC 250V, 5.0A
Indicators
2 light-emitting diodes
Colours: red, yellow, green or to
customer’s specification
(standard: “On” = red, “O?” = green)
1 zero-potential switch contact
for “On”, 1 for “O?”
U ? AC 250V; I ? 2A; P ? 500 VA
Remote control con-
nections
Consumption
approx. 250 mW
Voltage
DC 24 V (19 - 34 V)
? 8513 01 / ? 8513 11
DC 60 V (38 - 86 V)
? 8513 02 / ? 8513 12
DC 110 V (88 -120 V)
? 8513 03 / ? 8513 13
Timings
Impulse extension = running time
limitation
Standard: approx. 10 seconds (adju-
stable, 1-15 seconds)
Test voltage
Field side against indicator contact
and Field side against control side
4 kVe? (1 minute)
without pulse exten-
? 8513 0-
sion and running-time
limitation
with pulse extension
? 8513 1-
and running-time
limitation
Ordering Information
Type
Order No.
8513 01
310200
8513 02
310202
8513 03
310204
8513 11
310201
851312
310203
851313
310205